Rapid Immunopurification Technique Enables Accurate Determination of Mitochondrial Metabolites

By LabMedica International staff writers
Posted on 14 Sep 2016
Print article
Image: A scanning electron micrograph (SEM) of two mitochondria from mammalian lung tissue displaying their matrix and membranes (Photo courtesy of Wikimedia Commons).
Image: A scanning electron micrograph (SEM) of two mitochondria from mammalian lung tissue displaying their matrix and membranes (Photo courtesy of Wikimedia Commons).
A rapid immunopurification technique was used to isolate mitochondria with metabolite contents that were relatively undamaged by enzyme activity and free from components of other cellular organelles.

While metabolite profiling by mass spectrometry has been widely applied for research purposes at the whole-cell level, it is not routinely possible to measure the concentrations of small molecules in mammalian organelles. However, in a recent development in this field, investigators at the Whitehead Institute (Cambridge, MA, USA) have developed a method for the rapid and specific isolation of mitochondria that allows accurate quantification of this organelle's metabolite content.

Up to now, various methods of differential centrifugation have been used to isolate mitochondria. Unfortunately, these protocols also precipitate non-mitochondrial material and other organelles. In addition, these relatively lengthy procedures promote enzymatic modifications of mitochondrial metabolites that lead to variable results.

The investigators described a novel immunopurification technique for isolation of mitochondria in the August 25, 2016, issue of the journal Cell. The method was based on antibody-covered beads that bound to specific mitochondrial surface markers. Recovery of antibody-bead-mitochondria complexes permitted rapid disruption of the mitochondria and inhibition of all enzymatic activity within 10 minutes. The immunopurification technique was used it in tandem with a database of predicted mitochondrial metabolites ("MITObolome") to measure the matrix concentrations of more than 100 metabolites across various states of mitochondrial respiratory chain (RC) function.

"The advantage of this new method is that it offers a combination of both increased speed and specificity," said senior author Dr. David Sabatini, professor of biology at the Whitehead Institute. "We are quite excited about applying this workflow in vivo and to other organelles such as lysosomes."

Related Links:
Whitehead Institute

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
HLX
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: The cobas Malaria test is the first FDA-approved molecular test to screen U.S. blood donors for malaria (Photo courtesy of Roche)

First FDA-Approved Molecular Test to Screen Blood Donors for Malaria Could Improve Patient Safety

Malaria, a serious illness that often leads to death, is spread by a specific mosquito species that infect humans with a parasite. Other transmission modes include blood transfusions, organ transplants,... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The medical office procedure detects the key biomarker in Parkinson’s and related neurodegenerative diseases (Photo courtesy of BIDMC)

Simple Skin Biopsy Test Detects Parkinson’s and Related Neurodegenerative Diseases

Parkinson's disease and a group of related neurodegenerative disorders known as synucleinopathies impact millions globally. These conditions, including Parkinson’s disease (PD), dementia with Lewy bodies... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.