We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
RANDOX LABORATORIES

Download Mobile App




Smart Palm-size Optofluidic Hematology Analyzer Enables POCT of Patients’ Blood Cells

By LabMedica International staff writers
Posted on 17 Jan 2024
Print article
Image: Principle and construction of the palm-size optofluidic hematology analyzer (Photo courtesy of OES)
Image: Principle and construction of the palm-size optofluidic hematology analyzer (Photo courtesy of OES)

Variations in blood cell concentration can be indicative of several health conditions, including infections, inflammatory diseases, malignant blood disorders, and AIDS (Acquired Immune Deficiency Syndrome). Detecting these variations is crucial for diagnosing, treating, and managing these diseases. Traditional methods for measuring blood cell concentration, like using a hemocytometer, typically require an optical microscope. Alternatively, flow cytometers offer a more efficient method for sorting and counting blood cells in fluids, but they are often large and complex, weighing between 9-30 kg, thus limiting their use to laboratory and hospital settings. This restricts the availability of point-of-care testing (POCT) and can delay treatment for patients. Now, a proposed portable smart blood cell analyzer could help overcome the limitations of conventional methods for blood cell concentration detection.

Developed by the Harbin Institute of Technology (HIT, Heilongjiang, China), this innovative analyzer integrates a miniature fluorescence microscope, typically used in neuroscience and behavioral research, with a microfluidic platform. This design significantly reduces the analyzer's size and weight, resulting in a device that measures 35 × 30 × 80 mm and weighs only 39 g, making it substantially lighter than conventional flow cytometers. The analyzer combines image processing with leukocyte counting algorithms to enhance leukocyte information and accurately determine their concentration.

The effectiveness of the proposed analyzer was validated by comparing its leukocyte concentration measurements with those of a standard hemocytometer using Passing-Bablok analysis, achieving a correlation coefficient of 0.979. A Bland-Altman analysis further confirmed the analyzer’s reliability, establishing a 95% limit of agreement ranging from -0.93×10³ to 0.94×10³ cells/μL. The analyzer's error rate in calculating leukocyte concentration was found to be less than 10%, meeting the accuracy standards set by both the UK National External Quality Assessment Service (NEQAS) and the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88). The development of this palm-size optofluidic hematology analyzer is expected to facilitate the POCT of blood cells outside traditional hospital or laboratory settings, thus enhancing medical diagnosis in remote or underserved areas.

Related Links:
HIT

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A blood test could predict lung cancer risk more accurately and reduce the number of required scans (Photo courtesy of 123RF)

Blood Test Accurately Predicts Lung Cancer Risk and Reduces Need for Scans

Lung cancer is extremely hard to detect early due to the limitations of current screening technologies, which are costly, sometimes inaccurate, and less commonly endorsed by healthcare professionals compared... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: Comparison of traditional histopathology imaging vs. PARS raw data (Photo courtesy of University of Waterloo)

AI-Powered Digital Imaging System to Revolutionize Cancer Diagnosis

The process of biopsy is important for confirming the presence of cancer. In the conventional histopathology technique, tissue is excised, sliced, stained, mounted on slides, and examined under a microscope... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.